Product Description
Enerdrive 24V 30A DC2DC Battery Charger with MPPT
Description
The Enerdrive ePOWER DC2DC Battery Charger is a fully automatic multistage, multi input battery charger with the ability to charge from either an alternator linked to a battery; or via solar power with the in built Maximum Power Point Tracking (MPPT) Solar Controller.
Enerdrive ePOWER 24V – 30A DC2DC Battery Charger with MPPT
- Two totally independent DC Inputs for both engine and solar regulation charging one house battery bank output
- DC M6 screw terminals that will allow for large battery cable connection between all sources
- A dedicated Maximum Power Point (MPPT) solar regulator
- The same battery algorithms as included in our AC mains ePOWER battery charger including a specific lithium charging profile
- 30A output up to 40+°C with thermo controlled fan cooling
- Fully programmable LCD display to show which source is charging the battery along with charger status, voltage and amperage
- Temperature sensor included in charger for more accurate battery charging
The Enerdrive ePOWER DC2DC Battery Charger is a fully automatic multistage, multi input battery charger with the ability to charge from either an alternator linked to a battery; or via solar power with the in built Maximum Power Point Tracking (MPPT) Solar Controller. With two inputs available, the house battery will be charged from either the engine while underway, or via the solar panels when stationary. The process to choose either engine or solar is fully automatic and both functions are controlled from within the unit itself without the need for external relays.
During normal operation the ePOWER DC2DC Battery Charger will do a full charge cycle to float stage on the house battery bank with ability to choose either GEL, AGM, Flooded, Custom Programmable or Lithium. Once float stage is reached the charger transitions to a power supply mode to support any on-board DC loads.
Multistage Charging Process
The ePOWER DC2DC Battery Charger is a fully automatic, set and forget charger. It is designed to quickly and accurately recharge your deep cycle batteries utilising charger algorithms that help to maximise the life of your specialised deep cycle batteries.
The ePOWER DC2DC Battery Charger features multistage smart charging technology that enables the charger to be connected to your battery banks permanently. With the input of multiple sources, you can be assured of charging your batteries whenever underway; or when the sun is shining on your solar array.
As dictated by battery manufacturer’s recommendations, deep cycle batteries require a multistage charge sequence for perfect, fast and accurate charging. The Enerdrive ePOWER DC2DC smart charger delivers three primary charge stages.
Stage 1 – Bulk or Boost charge; The battery is charged at full rated output current of the charger until the battery reaches its final charging voltage, known as its absorption voltage. In this step, around 80% of the battery is recovered as fast as possible.
Stage 2 – Absorption Charge; With the charger voltage held steady, the remaining 20% is replaced with the charger allowing the current to taper off as the battery approaches full charge.
Stage 3 – Float; Finally, in the float stage the charger voltage is lowered and held at a constant and safe predetermined level. This prevents the battery from being overcharged, yet allows the charger to supply enough current to make up for the self-discharge losses of the battery, while supporting any additional loads connected to the battery (such as DC lighting and refrigerators). This stage allows for the charger to be used as a DC power supply.
Smart Charging Feature
The ePOWER DC2DC Battery Charger will regulate its output based on the loads connected to your battery banks. This function is important to maintain the life of your battery banks as some battery chargers mistake loads for discharge and continue to keep the batteries in the bulk or absorption stage for extended periods of time, which will damage the battery bank. The ePOWER DC2DC Battery Charger has two methods of load based regulation to ensure your battery charger transitions to float when it should do so.
Battery Temperature Sensor
Included standard with all ePOWER Battery Chargers.
Battery Charger Voltage
Battery Type | Absorption | Float | Equalisation |
---|---|---|---|
GEL | 28.8V | 27.4V | N.A. |
AGM | 29.4V | 27.2V | N.A. |
Flooded | 28.8V | 26.5V | 31V (see note 1) |
Lithium | 27.8V-29.2V (0.2V Step) (see Note2) | 27V-28.4V (0.2V Step) | N.A. |
Program (Custom) | 27.6V-29.6 (0.2V Step) | 26.0V-27.6 (0.2V Step) | N.A. |
Note: Specifications subject to change without notice. |
* For Concorde™ branded batteries (lifeline, sun xtender) use flooded setting and consult battery supplier for equalisation recommendations.
Note 1: Equalisation setting can only be used on flooded battery type selection only. See more details on Procedure to Equalise the Flooded Battery.
Note 2: Charger will terminate charging when charging current drops to below the set charger termination value.
Note 3: Charger is acting as a power supply with selected constant output voltage and preset maximum output current.
NOTE: The equalisation function although included in the ePOWER DC2DC will rarely be used. To activate the battery bank must be in float, and manually activated. A typical drive will not be long enough for the DC2DC function to complete the process. The MPPT Solar function may provide enough time for Equalisation, but the best recommendation will be an AC powered battery charger.
Battery Bank Size Recommendation
The battery charging current rating is based on the battery size. The battery bank should meet the minimum Ah rating as shown. If a smaller size battery bank is used, set the current rating to a lower value to match with the battery bank size. Normally, the minimum battery bank capacity is based on a C5 rating of the battery for charging.
Enerdrive DC2DC Battery Charger EN3DC30-24V | ||||
---|---|---|---|---|
Current Setting | 5A | 10A | 20A | 30A |
Battery Capacity | Min 25Ah | Min 50Ah | Min 100Ah | Min 150Ah |
Current Setting | ||||
---|---|---|---|---|
Bulk (“h” Setting) | 5A | 10A | 20A | 30A |
ABS-Float (“L” Setting) | 0.3A/ 0.5A/ 1A | 0.5A/ 1A/ 2A | 1.0A / 2A / 4A | 1.5A/ 3A/ 6A |
Note: Use the above table to set the Bulk and its related Absorption (ABS) to Float Charge Current.
IMPORTANT NOTE: If in doubt of the “L” Setting, use the highest available current setting for battery protection.
Unit Setting for Lithium Type Battery (Voltage and Current):
Lithium Voltage Setting : 27.8 – 28.8 (0.2V Step) – EN3DC30-24V (Current Setting) | ||||
---|---|---|---|---|
Charge Current | 5A | 10A | 20A | 30A |
Terminate Current | 0.3A/ 0.5A/ 1A | 0.5A/ 1A/ 2A | 1.0A / 2A / 4A | 1.5A/ 3A/ 6A |
Note: The return to charge voltage setting for Lithium Type battery is set to 26.6Vdc
Specifications
24V 30A DC to DC Battery Charger
Model | EN3DC30-24V |
---|---|
Output Rating | |
Output Voltage | 24V Nominal (17.0V min) |
Output Current (Maximum) | 30A |
Output Power | 865W |
Charger DC Output (CH1): | |
Selectable Battery Type | Gel, AGM, Flooded, Lithium, Program |
Charger Voltage Range | 27.6V – 31.0V |
Float Voltage Range | 26.0V – 27.6V |
Charger Current (User Selectable) | 5 / 10 / 20 / 30A (default 30A) |
Equalize Voltage (Flooded Battery) | 31.0V |
Equalize Charging Current | 10% of Bulk Current Setting |
Charging Control | 2 stage / 3 stage selectable (Default 3 Stage) |
DC Output Bank | Single |
Current draw from CH1 when not operating | ≤50 mA |
Battery Temperature Setting | Low/ Normal/ High (Battery Temperature Sensor Standard) |
Efficiency | 95% |
INPUT Rating (CH2 – MPPT Solar) | |
Input Voltage | 14.5 – 45VOC |
Maximum Solar Input | ≤23V input, 500W (600W allowable) ≥37.5V-45V input, 800W (1000W allowable) |
INPUT Rating (CH3 – Start/Alternator) | |
Input Voltage | 10.5 – 16VDC / 21 – 32VDC |
Dimensions | |
Height x Width x Depth | 242mm x 172mm x 74mm |
Unit Weight | 1.85 Kg |
Shipping Weight | 2.17 kg |
Note: Specifications subject to change without notice.
Downloads
- User Manual Rev 1.5 (902kb)
- Appendix A1 Rev 1.0 (436kb)
- Appendix A2 Rev 1.0 (293kb)
- Appendix A3 Rev 1.0 (241kb)
- ePOWER DC2DC Battery Charger Wiring Diagram
- ePOWER DC2DC Battery Charger Wiring Diagram V2
- DC2DC Remote Panel Installation/Operations Manual